AquilaServer Upgrade Instructions

From EHS Help
Revision as of 12:15, 27 January 2016 by Admin (Talk | contribs)

Jump to: navigation, search

This is a Technical (IT) Instructions topic


Pre-requisites

  • Any existing AquilaServer must be installed and working correctly. This should not be uninstalled.
  • It's preferable, but not essential, to ensure that all client users are on desktop version.

Overview

  • The upgrade will take between 15 - 120 minutes depending on the size of your iBID database.
  • Replacing the necessary files takes < 1 min, during which time the application will be unavailable.
  • The upgrade also re-calculates the analysis data in the database in order to implement new and changed formulae for the national reports, dashboard reports etc. During the analysis re-calculation, the system will be available to end-users, however performance may be affected slightly.

Instructions

  • Backup the IBID database to provide fall-back in the event of a failure. Installations for older versions of the server are readily available, should a major roll-back be required.
  • Download the "iBID Server vX.X Upgrade (32-bit)" (filename aquilaserver_upgrade32.exe) from ibidb.org. where X.X is the new version number
  • On the machine where AquilaServer is currently installed, run the aquilaserver_upgrade32.exe
  • Follow on-screen instructions. You will see:
    • a console window appear immediately before copying files - this is the stopping of the AquilaServer service
    • a console window appear immediately after copying files -- this is the restarting of the AquilaServer service (after which the application is available for use)
    • a final console window will appear that makes any necessary metadata changes to the database & recalculates the iBID analysis data

Rollback

In the event of a problem during the server upgrade, the roll-back process is as follows:

  • Contact EHS who will be able to supply files for the previous version of AquilaServer.
  • Replace the file on your system with those provided by EHS.
  • Ensure the AquilaServer process is not running, either via the Services control panel app, or via the command prompt with "net stop AquilaServer".
  • Restore the database from the backup taken immediately before the upgrade process.
  • Start the AquilaServer process again, either via the Services control panel app, or via the command prompt with "net start AquilaServer".

Support

See Getting support