| + | # Remove/rename existing cgi-bin\AquilaWeb.exe file to prevent further audit trail uploads from burn services | ||
# Stop the rebuilder service | # Stop the rebuilder service | ||
# Backup the database & verify | # Backup the database & verify | ||
| − | # Run | + | # Run SQL script to update the database & check for zero errors: '''[http://evolutionhealthcaresystems.co.uk/downloads/doc_details/76-ms-sql-ibid-v39-upgrade-script iBID DBv39 Upgrade SQL Script]''' |
| − | + | # Run AquilaServer_2.2_upgrade_32-bit_No-recalc.exe file: '''[http://evolutionhealthcaresystems.co.uk/downloads/doc_details/77-aquilaserver-upgrade-to-22-no-recalculations AquilaServer v2.2 Upgrade]''' | |
| − | # Run | + | # Deploy the supplied AquilaWeb.exe module: '''[http://evolutionhealthcaresystems.co.uk/downloads/doc_details/78-aquilaweb-22-iis-module AquilaWeb v2.2]''' |
| − | + | # Restart the rebuilder service | |
| − | # Deploy the supplied AquilaWeb.exe | + | |
| − | + | ||
| − | # | + | |
Latest revision as of 09:02, 3 May 2016
This is a Technical (IT) Instructions topic
Procedure
- Remove/rename existing cgi-bin\AquilaWeb.exe file to prevent further audit trail uploads from burn services
- Stop the rebuilder service
- Backup the database & verify
- Run SQL script to update the database & check for zero errors: iBID DBv39 Upgrade SQL Script
- Run AquilaServer_2.2_upgrade_32-bit_No-recalc.exe file: AquilaServer v2.2 Upgrade
- Deploy the supplied AquilaWeb.exe module: AquilaWeb v2.2
- Restart the rebuilder service
Recovery on Upgrade Failure
At any point should the upgrade fail the recovery procedure is:
- Restore the database from the backup
- Uninstall any version of AquilaServer & install the previous version of AquilaServer (available from EHS)
- Remove the latest version of AquilaWeb & replace with previous version (available from EHS)
- start the rebuilder & re-schedule