==Overview==
+
== Pre-Requisites ==
  
 
* Any existing AquilaServer must be installed and working correctly.  It should not be uninstalled.
 
* Any existing AquilaServer must be installed and working correctly.  It should not be uninstalled.
* All users should ideally be off the system.
+
* Backup the database to provide fall-back in the event of a failure.  (Installations for older versions of the server are readily available, should a major roll-back be required).
* Backup the IBID database to provide fall-back in the event of a failure.  (Installations for older versions of the server are readily available, should a major roll-back be required).
+
* On the machine where AquilaServer is currently installed, run the file AquilaServer_N.N_upgrade_32-bit.exe
+
* Upgrade each client as necessary
+
* See also [[Aquila Server Configuration]]
+
  
 
== Before Upgrade==
 
== Before Upgrade==
  
* Download the AquilaServer upgrade from here: [https://www.evolutionhealthcaresystems.co.uk/downloads/#aquila-upgrade www.evolutionhealthcaresystems.co.uk/downloads]  (login required)
+
* All users should ideally be off the system.
* Ensure you have backed up the AquilaCRS database using appropriate platform tools.
+
* Download the AquilaServer upgrade from here: [https://www.evolutionhealthcaresystems.co.uk/download/aquila-server-upgrade/ https://www.evolutionhealthcaresystems.co.uk/download/aquila-server-upgrade/]  (login required)
  
 
== Running the Upgrade ==
 
== Running the Upgrade ==
  
* Run the upgrade app and check the introductory screens & ensure your system meets any new minimum system requirements if presented.
+
* Run the upgrade app (AquilaServer_N.NN_Upgrade_32-bit.exe) and check the introductory screens & ensure your system meets any new minimum system requirements if presented.
 
* During the file replacement stage, the server will be unavailable to end users.
 
* During the file replacement stage, the server will be unavailable to end users.
  

Revision as of 17:19, 10 November 2020

This is a Technical (IT) Instructions topic

Pre-Requisites

  • Any existing AquilaServer must be installed and working correctly. It should not be uninstalled.
  • Backup the database to provide fall-back in the event of a failure. (Installations for older versions of the server are readily available, should a major roll-back be required).

Before Upgrade

Running the Upgrade

  • Run the upgrade app (AquilaServer_N.NN_Upgrade_32-bit.exe) and check the introductory screens & ensure your system meets any new minimum system requirements if presented.
  • During the file replacement stage, the server will be unavailable to end users.

AqServerUpgrade 3.png

  • AquilaServer is stopped, files are replaced and AquilaServer is restarted (2-3 minutes):

AqServerUpgrade 4.png

  • Database upgrade starts (5-10 minutes):

AqServerUpgrade 5.png

  • CAUTION: If there are any issues with the database upgrade, they will appear here
    • Do not proceed with the installation
    • Report any issues to the help desk immediately on 01964 503400 or see Getting support

Analysis Recalculations

  • Following the upgrade the internally calculated analysis data may be recalculated to reflect any changes in the formula.
  • These recalculations will take some time, depending on the amount of data, hardware specifications, etc.
  • The system is available whilst these calculations are running, although users may perceive a slight performance hit. Depending on your available resources, you may prefer to wait until this has completed.
  • If you want to allow user access during the Calculatoins, re-open port 8099 on the server if you closed it initially - otherwise wait until the calculations have completed.

AqServerUpgrade 6.png

  • Calculations completed:

AqServerUpgrade 7.png

Rollback

In the event of a problem during the server upgrade, the roll-back process is as follows:

1) Contact EHS who will be able to supply files for the previous version of AquilaServer. 2) Use the Aquila Server Configuration tool to make a careful note of your settings. 3) Uninstall the AquilaServer product 4) Restore the database from the backup taken immediately before the upgrade process. 5) Install the previous version of AquilaServer as supplied, using the settings you noted in step 2.


Support

See Getting support